The current package reads like an early site planning sheet rather than a full civil permit package. Parking quantity does not appear to be the main problem. The key problem is that major compliance items are either missing or not documented at a level that supports agency or permit review.
| Severity | Issue | Location | Recommended Fix |
|---|---|---|---|
| High | Drainage and stormwater design are not adequately documented. | Entire site, especially the building pad and Highway 5 frontage. | Add grading and drainage sheets with spot grades, flow arrows, inlets, pipe sizes, rim and invert data, outfall tie-ins, and signed/sealed drainage calculations. |
| High | Highway frontage access and ditch work are not tied to agency approval. | Highway 5 / Old Stagecoach Road frontage and driveway entrance area. | Add ARDOT permit reference, driveway geometry, frontage grading tie-in, and any ditch or culvert sizing and flowline data tied to the access work. |
| Medium-High | ADA parking and accessible route cannot be fully verified. | Accessible stalls and route to the building entrance. | Add a dedicated ADA detail showing stall widths, aisle widths, van designation, signage, slopes, curb-ramp connection, and the full accessible route. |
| Medium | Utility design is too incomplete to confirm constructability and review compliance. | Water, sewer, fire, and service connections throughout the site. | Add proposed utility routing, sizes, materials, service connection points, fire service scope, invert and rim data where applicable, and utility conflict notes. |
| Medium | Boundary and easement verification are not fully supportable from the sheet alone. | Property lines, easement areas, and frontage dedication areas. | Pair the plan with the sealed boundary survey, title commitment, recorded plat, and all easement instruments before final approval. |
| Medium | Sidewalk detail contains an internal drafting inconsistency. | Sidewalk detail note block. | Recheck the concrete strength callout. The shown 400 PSI note appears likely to be a drafting error and should be corrected before issuance. |
| Low | Title block and contact data are incomplete. | Lower-right title block. | Complete owner and developer contact fields and confirm issuance status before external submittal. |